With the inclusion of Chapter <86> in the USP, QC labs can now more easily incorporate rCR into their quality testing. As of April 2026, PyroSmart NextGen® has been approved by 7 global regulatory agencies as an alternative to LAL reagents for a release testing of a novel MRI contrast media API.
PyroSmart NextGen® enhances your sustainability profile by eliminating the need for use of horseshoe crab-derived LAL reagent. This recombinant alternative reduces supply chain challenges while supporting your ESG goals.
Your Journey From LAL to rCR Begins Here
Transitioning from traditional LAL reagents to PyroSmart NextGen® doesn’t have to be complicated. Our interactive brochure provides a clear, easy-to-follow pathway designed to help users confidently navigate the evolution of bacterial endotoxin testing.
Product Details
Sensitivity
The maximum sensitivity of PyroSmart NextGen® depends on the type of reader that is used for assay:
- 0.005 EU/mL when run in an incubating microplate reader
- 0.001 EU/mL when run in Pyros Kinetix® Flex tube reader.
The sensitivity of each assays is determined by the lowest standard concentration on the standard curve used for the assay.
Sample to Lysate RatioS
Sample to PyroSmart NextGen® ratio is dependent on the reader: is used at economical volumes:
- Microplate reader: 1:1 ratio (using 50 µL: 50 µL)
- Pyros Kinetix® Flex tube reader: 4:1 (200 µL of test sample: 50 µL of PyroSmart NextGen®)
Performance
The PyroSmart NextGen® reaction mixture is incubated at 37±1°C and read in a microplate reader or tube reader equipped at 405 nm wavelength. The incubation time depends on the lowest standard concentration in the standard curve, with 0.005 EU/mL consistently achievable in 2,500 seconds in a microplate reader and 0.001 EU/mL achievable in 3,000 seconds in a tube reader, respectively. Thanks to the reproducibility of this reagent, the incubation times are lot independent. Software is used to construct the standard curve and calculate the endotoxin concentrations.
Stability
PyroSmart NextGen® is a lyophilized reagent with an excellent shelf life of 3 years from the date of manufacture.
Reconstitution
PyroSmart NextGen® is provided co-lyophilized with the chromogenic substrate, and as such, it is ready to use following a simple reconstitution (using 2.8mL of the supplied reconstitution buffer).
Packaging
PyroSmart NextGen® reagent is available in multiple kit configurations.
The standard configuration includes, 2 vials of reagent and 2 vials of reconstitution buffer, sufficient for a total of 100 wells (approx. 50 wells/vial).
High‑throughput configurations are available. Please enquire for further details.
Safety Data Sheets
Click on the links below to view Safety Data Sheets.
United States
PyroSmart NextGen® Recombinant LAL Reagent
PyroSmart NextGen® Reconstitution Buffer
United Kingdom
PyroSmart NextGen® Recombinant LAL Reagent (BE)
PyroSmart NextGen® Reconstitution Buffer (BE)
Europe
PyroSmart NextGen® Recombinant LAL Reagent (DE)
PyroSmart NextGen® Recombinant LAL Reagent (ES)
PyroSmart NextGen® Recombinant LAL Reagent (FR)
PyroSmart NextGen® Recombinant LAL Reagent (IT)
PyroSmart NextGen® Recombinant LAL Reagent (PT)
Pyrochrome® Reconstitution Buffer (DE)
Pyrochrome® Reconstitution Buffer (ES)
Pyrochrome® Reconstitution Buffer (FR)
Pyrochrome® Reconstitution Buffer (IT)
Pyrochrome® Reconstitution Buffer (PT)
Canada
PyroSmart NextGen® Recombinant LAL Reagent (FR)
Pyrochrome® Reconstitution Buffer (EN)
Pyrochrome® Reconstitution Buffer (FR)
Mexico
PyroSmart NextGen® Recombinant LAL Reagent (ES)
Pyrochrome® Reconstitution Buffer (ES)
Product Literature
Click on the links below to view product literature.
Package Inserts
PyroSmart NextGen® Product Brochure
BPS Reports
Vol. 6 No. 2 p.68-75 2023 Title: A Demonstration of the Validation Process for Alternative Endotoxin Testing Methods Using PyroSmart NextGen® Recombinant Cascade Reagent - Corresponding Author: Madeline Kelley
Vol. 6 No. 1 p.11-15 2023 Title: Evaluation of Recombinant Cascade Reagent PyroSmart NextGen® and Limulus Amebocyte Lysate Equivalency in a Plate and Tube Reader for Bacterial Endotoxins Testing - Corresponding Author: Madeline Kelley
Vol. 5 No. 5 p.105-114 2022 Title: Advanced Recombinant Cascade Reagent PyroSmart NextGen® for Bacterial Endotoxins Test as Described in the Pharmacopeias - Corresponding Author: Ingrid Stevens, Norihiko Ogura
Training Video
FAQs
How does PyroSmart NextGen® (PSNG) recombinant cascade reagent (rCR) work?
PSNG utilizes recombinant Limulus amebocyte lysate (LAL) reagent technology for bacterial endotoxin testing, designed to closely mimic the natural endotoxin detection cascade. This recombinant cascade reagent combines the essential components Factor C, Factor B, and pro-clotting enzyme, ensuring high sensitivity and accuracy in bacterial endotoxin testing while eliminating the potential for (1→3)-β-D-glucan cross-reactivity.
What are the advantages of PyroSmart NextGen® (PSNG) over kinetic and gel-clot BET methods?
PSNG recombinant cascade reagent offers a familiar workflow, using the same methodology, instrumentation, and software as traditional LAL reagents. With minimal changes to standard operating procedures and minimal technician training required, transitioning to PSNG is seamless, straightforward, and supported by ACC experts.
How is PyroSmart NextGen® (PSNG) more sustainable than traditional BET methods?
Unlike traditional BET methods, PSNG does not rely on horseshoe crab blood or any naturally sourced reagents. This recombinant cascade reagent is a sustainable solution that aligns with your environmental and ethical goals.
What types of endotoxin testing is PyroSmart NextGen® (PSNG) suitable for?
PSNG can be used for various endotoxin tests, ranging from standard water testing to samples requiring high sensitivity, such as intrathecal products, and those requiring high dilutions to overcome interference.
Will PSNG perform the same as naturally sourced reagents?
Yes, PSNG is a kinetic chromogenic reagent. It contains recombinant Factor C, Factor B, and pro-clotting enzyme. Thus, it continues to rely on the cascade mechanism to amplify the signal. It is co-lyophilized with the same chromogenic substrate as other chromogenic reagents. Therefore, it is homogeneous with Pyrochrome® and Chromo-LAL. This presents a considerable advantage to the end user: they keep the method and only switch out the reagent.
What’s the difference between Recombinant Factor C (rFC) and Recombinant Cascade Reagent (rCR)?
Recombinant Factor C reagent contains only recombinant Factor C. This enzyme acts as a biosensor for endotoxin (binds explicitly to it). However, due to the absence of the cascade amplifying mechanism (Factor B and pre-clotting enzyme), rFC reagents must be paired with a fluorescence method. This means that a fluorescent plate reader must be used (along with a specific microplate). This constitutes a different measured entity, different instrumentation, and different preparation steps with a limited output (endpoint assay only). Unlike PyroSmart NextGen®, which features single-step reconstitution, rFC reagents require three reagents in a specific ratio and a 10-minute pre-incubation step.
How are recombinant reagents produced?
Recombinant reagents are produced through a biopharmaceutical process based on the use of expression systems as cell line clones that contain (thanks to genetic engineering) DNA coding Factor C, Factor B and pro-clotting enzymes from Limulus polyphemus. The cell lines express the final glycoproteins Factor C, Factor B and pro-clotting enzyme, which are then collected, purified, and formulated into PyroSmart NextGen®.
Product Codes
| Product Description | Product Code |
|---|---|
| Multi-Test 2.8 mL/vial (approx. 50 tests/vial) | |
| Each kit contains: 2x PyroSmart NextGen® Reagent, 2x Reconstitution Buffer | #PNG050-2 |
Partner with the LAL Experts
Ready to adopt a sustainable LAL reagent technology for bacterial endotoxin testing? Contact us to get expert guidance from the BET specialists at ACC. With our industry-leading support, we can help you transition from your current method to PyroSmart NextGen® recombinant cascade reagent. Our experienced team is here to support you every step of the way.